Skip to content
Fire Safety

Fire Door Regulations for Landlords 2026: A Complete Guide

fire door inspection 2026

Updated September 2026

Fire doors are easy to overlook because, most of the time, they look and behave like ordinary doors. In a fire, however, a correctly specified, installed and maintained fire door can help contain flames and smoke, protect an escape route and give residents more time to reach safety.

For landlords, freeholders and managing agents, looking after fire doors is therefore not simply a box-ticking exercise. It is part of managing the building’s overall fire risk.

This guide explains the main fire door responsibilities affecting residential landlords in England, how often certain doors must be checked, what a useful check should cover and when a competent fire door contractor is needed.

Important: This article provides general information for properties in England. The requirements that apply to a particular building depend on its use, height, layout, occupancy and fire risk assessment. Different legislation and guidance apply in Scotland, Wales and Northern Ireland. If you are responsible for a building and are unsure what is required, obtain advice from a competent fire safety professional.

Why are fire doors so important in rented property?

Fire doors form part of a building’s passive fire protection. Their purpose is to resist the spread of fire and, where the door is designed to control smoke, help restrict smoke movement as well.

In blocks of flats and other multi-occupied residential buildings, this can help:

  • keep communal corridors and stairways usable for longer;
  • prevent a fire in one flat or room from spreading quickly into shared areas;
  • preserve the building’s fire compartments;
  • support the evacuation or “stay put” strategy identified for the building; and
  • provide safer access for firefighters.

A fire door only performs as intended when the complete door assembly works together. The door leaf, frame, glazing, hinges, closer, latch, seals and other ironmongery all matter. A certified door leaf fitted badly—or fitted with incompatible components—may not provide the expected protection.

What fire door laws apply to landlords in England?

There is no single rule covering every rented home. The duties depend on the type of property and who has control of it.

For blocks of flats and buildings containing two or more domestic premises with common parts, the Regulatory Reform (Fire Safety) Order 2005 applies to the relevant areas. The Fire Safety Act 2021 clarified that this includes flat entrance doors between domestic premises and common parts.

The person or organisation with legal responsibility is known as the Responsible Person. Depending on the arrangements, this may be the building owner, freeholder, landlord, management company or another person with control of the premises. Appointing a managing agent to handle day-to-day tasks does not necessarily transfer the underlying legal responsibility.

The Fire Safety (England) Regulations 2022 add specific fire door duties for multi-occupied residential buildings.

Houses in multiple occupation are also subject to housing legislation, including the Management of Houses in Multiple Occupation (England) Regulations 2006, and locally enforced standards. The correct precautions for an HMO should be determined from the property and its risk—not copied from another building.

The starting point is a suitable and sufficient fire risk assessment. This should identify which doors need to be fire-resisting, whether their existing performance is appropriate and what inspection or maintenance regime is needed.

How often must fire doors be checked?

Under the government’s current fire door guidance for Responsible Persons, for a residential building containing two or more sets of domestic premises where the top storey is more than 11 metres above ground level, the Responsible Person must:

  • check fire doors in communal areas at least every three months; and
  • use best endeavours to check flat entrance fire doors at least every 12 months.

The annual flat entrance door requirement includes keeping a record of the steps taken to gain access where a check could not be completed.

In all multi-occupied residential buildings with common parts through which residents would evacuate, the Responsible Person must also give residents specified information about fire doors.

Residents should be told that fire doors must be kept shut when not in use, self-closing devices must not be tampered with and faults or damage should be reported immediately. This information must be given to new residents as soon as reasonably practicable and repeated to all residents at intervals not exceeding 12 months.

These are legal minimum frequencies for buildings within the scope of regulation 10; they are not automatically the right maintenance schedule for every door. Busy communal doors, doors in vulnerable settings or doors with a history of damage may need more frequent attention. Your fire risk assessment should inform the inspection programme.

Government guidance describes the regulation 10 checks as simple visual checks that appropriately instructed staff may be able to complete. That is different from a detailed condition survey or technical inspection by a competent fire door specialist.

A practical fire door checklist for landlords

A routine visual check should be systematic and recorded against a unique door reference. Look at the complete doorset rather than the door leaf alone.

1. Does the door close fully?

Open a self-closing door fully and release it. Then repeat the check from a partly open position. It should close completely into the frame and overcome the latch, seals and any floor resistance without assistance.

A door that stops short, catches on the floor, slams dangerously or needs to be pulled shut requires attention. Do not disconnect or adjust a closer unless the person doing the work is competent to do so.

2. Are the door and frame damaged?

Look for splits, holes, warping, loose sections, impact damage and unauthorised alterations. Check that the frame appears secure and that there is no obvious damage around locks, letterplates, viewers or glazing.

Damage should not be covered with a cosmetic repair before its effect on fire performance has been assessed.

3. Are the gaps consistent and appropriate?

Excessive or uneven gaps can allow fire and smoke to pass through prematurely. The latest government fire door guidance states that the gap between the door and frame should never exceed 4 mm.

At the bottom, the gap should be as small as practicable while allowing the door to operate without snagging. The specification and evidence for the particular doorset must also be considered.

A coin is not a reliable compliance tool. If gaps appear excessive, inconsistent or outside the product specification, arrange a competent inspection.

4. Are the seals present and intact?

Check the intumescent strips and, where fitted, cold-smoke seals around the door or frame. They should be continuous, securely fitted and free from paint build-up, damage or missing sections.

Do not assume that every door needs the same seal arrangement. Components should match the evidence for the particular doorset and the building’s fire strategy.

5. Are the hinges and other components secure?

Check for missing screws, loose hinges, visible wear or damage. Glazing, letterplates, locks, latches, hold-open devices and other hardware must be suitable and compatible with the fire door assembly.

Unapproved alterations—such as fitting a new smart lock, cutting in a letterbox or replacing glazing—can compromise the door’s performance.

6. Has anything stopped the door working?

Fire doors should not be wedged open. Check for door wedges, hooks, objects stored in the swing path, thick flooring, damaged seals or poorly fitted access-control equipment that prevents full closure.

Where a door needs to be held open for accessibility or operational reasons, use a suitable fire-alarm-linked or otherwise appropriately risk-assessed hold-open solution. A door wedge is not a substitute.

7. Is the door correctly identified and documented?

Look for certification plugs, labels or other traceable evidence where available, but do not treat the absence of a visible label as proof that an existing door must automatically be replaced.

Current government guidance makes clear that the 2022 Regulations do not require wholesale replacement merely because an existing flat entrance door was not manufactured and certified to the current standard for a new door.

The door’s suitability should be considered through the fire risk assessment and available evidence. Where its condition, specification or installation is uncertain, a competent survey can establish the next step.

Routine checks and professional fire door surveys are not the same

Routine landlord or caretaker checks are useful for spotting obvious changes between inspections: a closer has stopped working, a seal has been damaged or a resident has altered a front door.

A professional fire door survey goes further. Depending on the agreed scope, it may assess and document the leaf and frame, gaps, seals, hinges, closer, glazing, apertures, ironmongery, signage, installation and available certification or product evidence.

Findings can then be prioritised by location, defect and risk. The government’s detailed fire safety risk assessment guide for sleeping accommodation also explains the role of fire-resisting doors within a wider fire safety assessment.

This distinction matters. A visual check required by regulation 10 assumes that the fire risk assessment has already considered whether the door itself is suitable. It should not be used to certify an unknown door or replace a competent technical assessment.

Should a defective fire door be repaired or replaced?

Not every defect means a complete replacement is necessary. Depending on the doorset, its evidence and the extent of the damage, suitable remedial work may include:

  • adjusting or replacing a closer;
  • correcting alignment or resolving appropriate gap issues;
  • replacing damaged seals;
  • repairing or replacing compatible hinges, latches or other ironmongery;
  • addressing suitable glazing or aperture defects; or
  • reinstating required signage.

Replacement may be the better option where the door or frame is substantially damaged, the assembly is unsuitable for its location, evidence cannot support a safe repair or previous alterations have compromised its integrity.

Avoid treating a survey as a shopping list for a general maintenance operative. Fire door repairs and replacements must preserve the tested or assessed performance of the complete assembly.

Government guidance states that where checks identify a need for repair or replacement, the work must be undertaken by a competent contractor as soon as reasonably practicable.

Indigo Systems provides fire door inspections, installation, maintenance and remedial works across London and the South East, helping landlords and property teams move from recorded defects to a practical programme of work.

What fire door records should landlords keep?

Clear records help demonstrate that faults are being managed rather than simply observed. They also make budgeting, resident access and follow-up work easier.

For each fire door, consider recording:

  • a unique asset or door number;
  • building, floor and precise location;
  • whether it is a flat entrance, stair, corridor, riser, cupboard or plant-room door;
  • inspection date and name of the person completing the check;
  • photographs of the door and any defects;
  • closer test result and condition of key components;
  • action required, priority and target date;
  • access attempts where a flat entrance door could not be checked;
  • repair or replacement details, including the contractor and completion date; and
  • the outcome of any post-work inspection.

Retain relevant product information, installation records and certificates with the building’s fire safety information. Records should be easy to retrieve and kept up to date when doors are altered or replaced.

Common fire door mistakes landlords should avoid

The most frequent problems are often ordinary maintenance or management failures rather than dramatic damage:

  • allowing residents or contractors to wedge communal doors open;
  • accepting a door that closes “most of the way”;
  • painting over or damaging smoke seals;
  • changing locks, letterplates or access-control hardware without checking compatibility;
  • fitting new flooring that obstructs the door;
  • carrying out isolated repairs without considering the whole doorset;
  • failing to re-check completed remedial work;
  • replacing every older door simply because it lacks modern markings; and
  • keeping no evidence of access attempts, defects or completed works.

A planned asset register and inspection schedule is far more reliable than waiting for residents to report a problem.

A simple action plan for landlords and managing agents

  1. Confirm responsibility. Establish who the Responsible Person is and who manages inspections, resident communication and repairs.
  2. Review the fire risk assessment. Make sure it covers relevant flat entrance and communal fire doors and reflects the current building.
  3. Build a door register. Give every relevant door a reference and record its location, type and known information.
  4. Set the correct checking frequency. Apply the statutory frequencies where relevant and increase them where use, risk or condition justifies it.
  5. Inform residents. Explain why fire doors must close, why closers must not be altered and how defects should be reported.
  6. Prioritise defects. Make safe, repair or replace defective doors according to competent advice and risk.
  7. Verify and retain evidence. Record completed works and confirm that the door closes and operates correctly afterwards.

Need help with fire doors in your building?

If you manage a block of flats, HMO, mixed-use development or residential portfolio, Indigo Systems can help you understand the condition of your fire doors and plan the next steps.

Our fire door service includes surveys, installation, repair, remedial works, replacement and ongoing maintenance across London and the South East.

Request a fire door survey or call 020 8681 1616 to discuss the building, number of doors and any existing reports.

Frequently asked questions

Do landlords have to install fire doors in every rental property?

No single requirement applies to every door in every rented home. The need for fire doors depends on the building type, layout, use, risk assessment, housing requirements and relevant building standards.

Blocks of flats, HMOs and properties with protected escape routes commonly require fire-resisting doors in specific locations. Obtain property-specific advice rather than assuming every internal door must be replaced.

How often should landlords inspect fire doors?

In multi-occupied residential buildings where the top storey is more than 11 metres above ground level, communal fire doors must be checked at least every three months and best endeavours must be used to check flat entrance doors at least every 12 months.

Other buildings and higher-risk doors may need a different or more frequent regime based on the fire risk assessment.

Can a landlord carry out fire door checks?

Simple visual checks under regulation 10 can be completed by suitably instructed staff and do not necessarily require a specialist.

A detailed survey, specification, repair or replacement requires the appropriate competence. A routine check cannot establish the fire performance of an unknown or unsuitable doorset.

Does an old fire door have to be replaced because it has no certificate?

Not automatically. Government guidance says the Fire Safety (England) Regulations 2022 do not require an existing flat entrance door to be replaced solely because it does not meet the certification standard applied to a new door today.

Its suitability, condition and performance still need to be considered through the fire risk assessment and competent advice.

Who pays for a flat entrance fire door?

Responsibility for the cost may depend on ownership, the lease, tenancy terms and the nature of the required work.

The Responsible Person still needs to ensure that fire safety duties are managed. Landlords and freeholders should review the relevant legal documents and obtain specialist advice where responsibility is disputed.

Can a fire door be repaired instead of replaced?

Sometimes. Closers, compatible seals, hinges and other defects may be capable of suitable remedial work. A badly damaged, inappropriate or unsupported doorset may need replacement.

The decision should be based on competent assessment and the evidence for the complete door assembly.